HPLC for today and tomorrow
[Outstanding Performance]
Two performance capabilities supporting data reliability: excellent reproducibility made possible by the pump and autosampler and excellent stability of the column oven and detector.
[Easy-to-use]
Along with simple operation and ease of use, Chromaster offers ease of maintenance, a critical requirement for HPLC.
[Robustness]
Hitachi’s reputation for instrument robustness and reliability continues with the Chromaster, which is built using stronger materials and manufactured with Hitachi’s strict quality control standards.
5110 Pump: Pressure up to 40 MPa
5160 Pump: Pressure up to 60 MPa
Operating Flow Rate:
Maximum Operating Pressure:
Dimensions: 340 (W) × 440 (D) × 140 (H) mm
Number of Mixed Solvents: Up to 4*
*Requires optional low-pressure gradient unit.
5260 Autosampler: 60 MPa withstand pressure, loop injection method
5280 Autosampler: 60 MPa withstand pressure, direct injection method
Sample Injection System:
Withstand Pressure: 60 MPa
Washing Function:
Sample Rack Temperature Control:
Sample Capacity:
Standard:
Optional:
5310: Horizontal Type
6310: Vertical Type
Temperature Setting Range:
Temperature Control Range:
Column Capacity: 300 mm × 3 columns (Maximum)
Built-in 3-Liter Water Tank:
Dimensions:
Optical System: Double-beam ratio photometric system
Wavelength Range: 190–600 nm
Flow Cell: Optical path length 10 mm
Simultaneous Measurement: Two-wavelength*
Dimensions: 340 (W) × 440 (D) × 140 (H) mm
Optical System: Single-beam ratio photometric system
Wavelength Range: 190–900 nm
Flow Cell: Optical path length 10 mm
Dimensions: 340 (W) × 440 (D) × 140 (H) mm
Optical System: Single-beam ratio photometric system
Wavelength Range: 190–900 nm
Flow Cell: Optical path length 10 mm
Simultaneous Measurement: Spectrum acquisition
Dimensions: 340 (W) × 440 (D) × 140 (H) mm
*Please contact us for additional details.
Light Source: Xe lamp with Hg lamp for wavelength verification
Wavelength Range:
Flow Cell: Irradiation volume 12 µL
Dimensions: 340 (W) × 440 (D) × 280 (H) mm
Refractive Index Range: 1 to 1.75
Temperature Control Range: OFF, 30–50°C
Dimensions: 340 (W) × 440 (D) × 140 (H) mm (excluding projections)
Measurement Mass Range (m/z): 20–1,000
Ion Source: Electrospray Ionization (ESI)
Dimensions: 440 (W) × 610 (D) × 430 (H) mm
N₂ Gas Usage: Maximum flow rate 3.4 L/min, pressure 300 ± 20 kPa
Output Power: DC 24 V, 450 W
Power Supply Capability: Supports one pump, one autosampler, one detector (UV Detector, UV-Vis Detector, Diode Array Detector, or RI Detector), and one interface control board.
Bottle Capacity & Space: